The function is to detect object surface relative humidity (RH).
Areas exceeding the configured threshold will be highlighted in green on the thermal
image.
-
In the palette bar area on the right side of thermal image, open Palette Settings, then select Condensation from the Palette
drop-down list.
-
Set the alarming RH threshold in Alarm
Threshold. Surfaces exceeding the threshold will be rendered with
green palette.
- Optional:
Adjust ambient temperature and RH parameters as required.
-
When Use Local Parameters is
disabled, the system calculates results using Environmental Temp and Relative Humidity from Temperature Analysis (device environment parameters
when taking the thermal images, read-only).
- When Use
Local Parameters is enabled, the system uses the
following Environmental Temp and
Relative Humidity (user configured
target object environment parameters) for calculation.