Condensation Detection

The function is to detect object surface relative humidity (RH). Areas exceeding the configured threshold will be highlighted in green on the thermal image.

  1. In the palette bar area on the right side of thermal image, open Palette Settings, then select Condensation from the Palette drop-down list.
  2. Set the alarming RH threshold in Alarm Threshold. Surfaces exceeding the threshold will be rendered with green palette.
  3. Optional: Adjust ambient temperature and RH parameters as required.
    • When Use Local Parameters is disabled, the system calculates results using Environmental Temp and Relative Humidity from Temperature Analysis (device environment parameters when taking the thermal images, read-only).

    • When Use Local Parameters is enabled, the system uses the following Environmental Temp and Relative Humidity (user configured target object environment parameters) for calculation.